WHY ANCORIX
Stable anchorage, comfort and versatility.

Precise wire-lock
Allows positioning of the orthodontic wire without movement or rotation; the applied mechanics remain where they were planned.

Rounded edges
Smooth-contour geometry for greater patient comfort throughout the entire period of use.

2 new geometries
Anterior TY and T2 plates expand the application possibilities and the range of planned movement.

Low profile
Low profile and high strength to ensure comfort, malleability and safety during installation.

Acessos rápidos
Technical documentation and support materials

Clinical application
Anatomy defines the anchorage point.
ANCORFIX is indicated for skeletal anchorage, with applications supporting orthodontic mechanics.
SR - Superior right
IR - Inferior right
SL - Superior left
IL - Inferior left
The model selection criteria depend on the conditions of the bone tissue and the location of the target anatomical site. It is the responsibility of the qualified professional to select the appropriate models to achieve the desired effect.
GEOMETRIES
Plates with wire-lock.
Ten geometries in two lines. ANC 2.0 with wire-guide and 2.0 Standard, covering anterior and posterior applications, in three lengths.
2.0 Line · with wire-guide
Standard Line · with wire-guide
Início
The surgical team sends CT/MRI scans and describes the goal of the procedure via portal or email.
Engenharia
3D reconstruction of the anatomy and device design by specialized biomedical engineers.
Cirurgião
O cirurgião revisa e aprova geometria, posicionamento e fixação em sessão remota antes da produção.
Production
Impressão 3D e usinagem em material certificado. Inspeção dimensional e embalagem estéril individual.
Delivery
Delivery ao centro cirúrgico com certificado de conformidade, rastreabilidade de lote e suporte técnico.
PROCESSO
Do exame ao centro cirúrgico
em 5 etapas.
Um fluxo claro, com etapas definidas e comunicação direta com a equipe de engenharia biomédica em cada ponto.

Planejamento baseado em imagem
A reconstrução 3D da tomografia do paciente é a base do projeto — não há extrapolação de tamanho ou geometria.
TC/RM origem de cada dispositivo
Validação cirúrgica pré-fabricação
O cirurgião revisa posicionamento, geometria e fixação em sessão remota antes de qualquer peça ser fabricada.
100% dos casos validados
Prazo previsível e rastreável
Cada etapa do fluxo tem prazo definido. O cirurgião recebe atualizações de status em tempo real do pedido.
30 dias úteis do aceite à entrega
Fabricação certificada
Production em ambiente ISO 13485, com rastreabilidade de lote, certificado de conformidade e embalagem estéril individual.
ISO 13485 gestão de qualidade
Precisão dimensional garantida
Tolerância de ±0,1 mm nos guias e implantes, verificada por inspeção dimensional antes do envio.
±0,1 mm tolerância dimensional
Technical support especializado
Engenheiros biomédicos disponíveis para discussão de caso, revisão de planejamento e suporte intraoperatório remoto.
+1.200 casos planejados

FIXATION
System screws.
Three fixation options in the system's 2.0 standard, identified by anodization color.

Instruments
Everything organized in one box.
O instrumental dedicado acompanha o sistema na Caixa Box 2.0, pronto para esterilização e rastreável por código.
T41.003
Drill Ø 1.6 × 5 × 50 mm
T41.004
Drill Ø 1.6 × 7 × 50 mm
T40.003
Medium cruciform connection
T40.004
Manual Screwdriver
MM3001
Angled forceps 18 cm
MM3002
Trident pliers 1.5/2.0
MM3003
Flat pliers 1.5/2.0 mm
MM3079
Flat pliers 1.5/2.0 mm

Recursos e Diferenciais
Cutting-edge technology combined with industrial reliability to maximize your productivity
Precisão anatômica
Desenvolvimento orientado por imagens e planejamento digital para favorecer adaptação e previsibilidade
Physiological design
Geometria pensada para respeitar a dinâmica da articulação temporomandibular
Engineering in medicine
Solutions built on the integration of technology, materials and surgical experience
Versatility of indication
Available in Standard and Custom versions for different clinical complexities
Technical support
Support from the CPMH team during the analysis, planning and case development stages
SLA Ativo
SLA-treated active surface creates microtexture that enhances cell adhesion and accelerates osseointegration.
Fluxo de pedido
A structured process from start to finish
01
Envio dos exames e informações do caso
CT, complementary exams and clinical documentation
02
Análise técnica e planejamento digital
Anatomical and functional assessment by a specialized team
03
Definição da solução mais adequada
Standard or Custom as needed
04
Validação do projeto
Approval according to clinical need
05
Fabricação do dispositivo
Production with advanced processes
06
Shipment for surgical use
Safe and traceable logistics
FAQ
Escolha a solução ideal para cada caso
Duas versões desenvolvidas para atender diferentes necessidades clínicas
Ambas as soluções fazem parte do ecossistema CPMH






















.png)